MAN LAN ANA Network Operations Report
04/04/2016 - 04/10/2016

MAN LAN ANA Network Operations Center
at Indiana University

New Connections

None


Upgrades

None


New Services

None


Unscheduled Outages Summary

Ticket Number Customer Impact Network Impact Title Outage Type Source Of Impact Start Time (UTC) End Time (UTC)


None during this report period

Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Start Time (UTC) End Time (UTC)

2471 3-Elevated 3-Elevated Maintenance - MAN LAN ANA (Amsterdam) Circuit Vendor04/08/2016 10:57 PM (No Data Available)

Scheduled Maintenances Detail

Ticket No.:2471:63
Subject:Maintenance - MAN LAN ANA (Amsterdam)
Source Of Impact:Vendor
Affected:Trans-Atlantic ANA-100G MAN LAN-Amsterdam
Start Time:Friday, April 8, 2016, 10:57 PM (2257) UTC
End Time:(No Data Available)
Description: The Trans-Atlantic ANA-100G circuit will be unavailable while Hibernia engineers perform maintenance to repair a shunt fault. An outage of up to a week is expected; however, the entire window is reserved. Should your path have a backup provisioned over the ANA-100 WIX-London path, your traffic should redirect.


Downtime and Availability



MAN LAN ANA Core NodesDown TimeReporting Period Availability52 Week Availability
sw.net.manlan.internet2.edu0 hr 0 min100.00000%99.83311%

Aggregate MAN LAN ANA Core Nodes0 hr 0 min100.00000%99.83311%

MAN LAN ANA Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
MAN-AMST-NEWY-100GE-0163049 hr 2 min70.81349%95.73891%

Aggregate All MAN LAN ANA Backbone Circuits49 hr 2 min70.81349%95.73891%




Upcoming Scheduled Maintenances