WIX ANA-100 Network Operations Report
09/21/2015 - 09/27/2015

WIX ANA-100 Network Operations Center
at Indiana University

New Connections

None


Upgrades

None


New Services

None


Unscheduled Outages Summary

Ticket Number Customer Impact Network Impact Title Outage Type Source Of Impact Start Time (UTC) End Time (UTC)

5342-High 2-High Instability Resolved - WIX ANA (London) PowerVendor 09/24/2015 6:40 PM 09/24/2015 7:57 PM

Unscheduled Outages Detail


Ticket No.:534:130
Subject:Instability Resolved - WIX ANA (London)
Source Of Impact:Vendor
Affected:Trans-Atlantic ANA-100 WIX-London
Start Time:Thursday, September 24, 2015, 6:40 PM (1840) UTC
End Time:Thursday, September 24, 2015, 7:57 PM (1957) UTC
Description:The above ANA-100 circuit is now stable. The vendor has been contacted and stated that the instability was due to faulty power equipment in London. Replacement of the equipment has been completed and no further instability expected. Should your path have a backup provisioned over the ANA-100 MAN LAN-Amsterdam path, your traffic should redirect.

Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Start Time (UTC) End Time (UTC)

None during this report period

Downtime and Availability



WIX ANA-100 Core NodesDown TimeReporting Period Availability52 Week Availability
sw.net.wix.internet2.edu0 hr 0 min100.00000%99.95332%

Aggregate WIX ANA-100 Core Nodes0 hr 0 min100.00000%99.95332%

WIX ANA-100 Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
WIX-LOND-WASH2-100GE-015301 hr 17 min99.23611%99.56436%

Aggregate All WIX ANA-100 Backbone Circuits1 hr 17 min99.23611%99.56436%




Upcoming Scheduled Maintenances

Ticket No.:529:130
Subject:Maintenance 1 of 3 - WIX ANA (London)
Affected:Trans-Atlantic ANA-100 WIX-London
Start Time:Saturday, October 3, 2015, 11:00 AM (1100) UTC
End Time:Saturday, October 3, 2015, 9:00 PM (2100) UTC
Description: The above will be unavailable while TATA Communication's dark fiber provider performs work to roll fibers to new cable. An outage of up to ten hours anticipated, however, the entire window is reserved. Should your path have a backup provisioned over the ANA-100 MAN LAN-Amsterdam path, your traffic should redirect. This is maintenance window 1 of 3.

Ticket No.:530:130
Subject:Maintenance 2 of 3 - WIX ANA (London)
Affected:Trans-Atlantic ANA-100 WIX-London
Start Time:Saturday, October 10, 2015, 11:00 AM (1100) UTC
End Time:Saturday, October 10, 2015, 9:00 PM (2100) UTC
Description: The above will be unavailable while TATA Communication's dark fiber provider performs work to roll fibers to new cable. An outage of up to ten hours anticipated, however, the entire window is reserved. Should your path have a backup provisioned over the ANA-100 MAN LAN-Amsterdam path, your traffic should redirect. This is maintenance window 2 of 3.

Ticket No.:531:130
Subject:Maintenance 3 of 3 - WIX ANA (London)
Affected:Trans-Atlantic ANA-100 WIX-London
Start Time:Saturday, October 17, 2015, 11:00 AM (1100) UTC
End Time:Saturday, October 17, 2015, 9:00 PM (2100) UTC
Description: The above will be unavailable while TATA Communication's dark fiber provider performs work to roll fibers to new cable. An outage of up to ten hours anticipated, however, the entire window is reserved. Should your path have a backup provisioned over the ANA-100 MAN LAN-Amsterdam path, your traffic should redirect. This is maintenance window 3 of 3.