Ticket No.: | 2469:63 |
Subject: | Outage Resolved - MAN LAN ANA (Amsterdam) |
Source Of Impact: | Vendor |
Affected: | ANA-100 MAN LAN-Amsterdam |
Start Time: | Sunday, March 20, 2016, 11:29 PM (2329) UTC |
End Time: | Monday, March 21, 2016, 6:38 AM (0638) UTC |
Description: | The MAN LAN Trans-Atlantic ANA-100G circuit is now available. Vendor
Engineers have been engaged and the Trans-Atlantic
vendor has been asked to investigate. The reason for the outage was due
to a defective card in Amsterdam. The card has been replaced resolving
this issue. Should your path have a backup provisioned over the
ANA-100 WIX-London path, your traffic was redirected. |
|