WIX ANA-100 Network Operations Report
08/31/2015 - 09/06/2015

WIX ANA-100 Network Operations Center
at Indiana University

New Connections

None


Upgrades

None


New Services

None


Unscheduled Outages Summary

Ticket Number Customer Impact Network Impact Title Outage Type Source Of Impact Start Time (UTC) End Time (UTC)

5132-High 2-High Brief Outage - WIX ANA (London) UndeterminedVendor 09/02/2015 11:14 AM 09/02/2015 11:17 AM
5182-High 2-High Outage Resolved - WIX ANA (London) Unannounced MaintenanceVendor 09/04/2015 9:04 PM 09/04/2015 10:13 PM
09/04/2015 10:19 PM 09/04/2015 10:20 PM

Unscheduled Outages Detail


Ticket No.:513:130
Subject:Brief Outage - WIX ANA (London)
Source Of Impact:Vendor
Affected:Trans-Atlantic ANA-100 WIX-London
Start Time:Wednesday, September 2, 2015, 11:14 AM (1114) UTC
End Time:Wednesday, September 2, 2015, 11:17 AM (1117) UTC
Description:The above ANA-100 circuit is now available after a brief outage. The vendor has been contacted; however, the outage that was experienced was too brief for any action to be taken by the network team. The fault of the outage is undetermined. Should your path have a backup provisioned over the ANA-100 MAN LAN-Amsterdam path, your traffic should have redirected.

Ticket No.:518:130
Subject:Outage Resolved - WIX ANA (London)
Source Of Impact:Vendor
Affected:Trans-Atlantic ANA-100 WIX-London
Start Time:Friday, September 4, 2015, 9:04 PM (2104) UTC
End Time:Friday, September 4, 2015, 10:13 PM (2213) UTC
Start Time:Friday, September 4, 2015, 10:19 PM (2219) UTC
End Time:Friday, September 4, 2015, 10:20 PM (2220) UTC
Description:The above ANA-100 circuit is now available. The vendor has been contacted; the reason for outage is unannounced maintenance in Wiltshire County, UK. The maintenance has been completed; no further outages are expected. Should your path have a backup provisioned over the ANA-100 MAN LAN-Amsterdam path, your traffic should have redirected.

Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Start Time (UTC) End Time (UTC)

None during this report period

Downtime and Availability



WIX ANA-100 Core NodesDown TimeReporting Period Availability52 Week Availability
sw.net.wix.internet2.edu0 hr 0 min100.00000%99.95332%

Aggregate WIX ANA-100 Core Nodes0 hr 0 min100.00000%99.95332%

WIX ANA-100 Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
WIX-LOND-WASH2-100GE-015301 hr 13 min99.27579%99.57935%

Aggregate All WIX ANA-100 Backbone Circuits1 hr 13 min99.27579%99.57935%




Upcoming Scheduled Maintenances

Ticket No.:515:130
Subject:Maintenance - WIX Peer GEANT (Frankfurt)
Affected:Peer GEANT (Frankfurt)
Start Time:Tuesday, September 8, 2015, 7:00 PM (1900) UTC
End Time:Wednesday, September 9, 2015, 5:00 AM (0500) UTC
Description: A portion of the circuit to GEANT (Frankfurt) in Washington, DC maybe experience brief outages while Hibernia performs circuit maintenance. GEANT should remain available at a reduced capacity while the work is being completed.