AMPATH Network Operations Report
2020-09-07 - 2020-09-13
AMPATH Network Operations Center
| Connector | Type | Date | Sponsor |
|---|
None
None
None
| Incident Number | Customer Impact | Network Impact | Title | Outage Type | Source of Impact | Current State | Start Time (UTC) | End Time (UTC) | Duration |
|---|---|---|---|---|---|---|---|---|---|
| INC0064786 | 4 - Low | 2 - High | Brief Outage Resolved - AMPATH Provider LANautilus FIU031WCRPPANNN | Unannounced Maintenance | Vendor | Resolved | 2020-09-07 07:17:01 | 2020-09-07 07:18:00 | 0 days 0 hr 0 min |
| INC0064896 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU026UMI2SA1NN | Undetermined | Vendor | Resolved | 2020-09-09 16:33:00 | 2020-09-09 16:34:00 | 0 days 0 hr 1 min |
| INC0065028 | 2 - High | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU035WMI2CRPNN | Circuit - Cut Fiber | Vendor | Resolved | 2020-09-11 04:04:18 | 2020-09-11 05:17:47 | 0 days 1 hr 13 min |
| Ticket No.: | INC0064786 |
| Subject: | Brief Outage Resolved - AMPATH Provider LANautilus FIU031WCRPPANNN |
| Source Of Impact: | Vendor |
| Affected: | FIU031WCRPPANNN |
| Current State: | Resolved |
| Start Time: | 2020-09-07 07:17:01 |
| End Time: | 2020-09-07 07:18:00 |
| Description | The listed asset is available following a brief outage. AMPATH and LANautilus Engineers have been contacted. The reason for the outage was maintenance. Maintenance has been completd. No further outages are expected. |
| Ticket No.: | INC0064896 |
| Subject: | Brief Outage - AMPATH Provider LANautilus FIU026UMI2SA1NN |
| Source Of Impact: | Vendor |
| Affected: | FIU026UMI2SA1NN |
| Current State: | Resolved |
| Start Time: | 2020-09-09 16:33:00 |
| End Time: | 2020-09-09 16:34:00 |
| Description | The listed asset is available following a brief outage. AMPATH and LANautilus Engineers have been contacted. However, the reason for the outage was unable to be determined due to the shortness of the outage. |
| Ticket No.: | INC0065028 |
| Subject: | Outage Resolved - AMPATH Provider LANautilus FIU035WMI2CRPNN |
| Source Of Impact: | Vendor |
| Affected: | FIU035WMI2CRPNN |
| Current State: | Resolved |
| Start Time: | 2020-09-11 04:04:18 |
| End Time: | 2020-09-11 05:17:47 |
| Description | The following asset is available. LANautilus engineers have been notified. The reason for the outage was due to a fiber cut in Florida. Splicing has been completed and no further impact is expected. |
| Ticket Number | Customer Impact | Network Impact | Title | Maintenance Type | Source Of Impact | Current State | Start Time (UTC) | End Time (UTC) | Duration |
|---|---|---|---|---|---|---|---|---|---|
| CHG0045534 | Maintenance Complete - AMPATH Provider Crown Castle | Circuit | Vendor | Closed | 2020-09-12 04:00:00 | 2020-09-12 10:00:00 | 0 days 6 hr 0 min | ||
| Ticket No.: | CHG0045534 |
| Subject: | Maintenance Complete - AMPATH Provider Crown Castle |
| Source Of Impact: | Vendor |
| Affected: | AMPATH-BOCA-MIAMI-DF |
| Current State: | Closed |
| Start Time: | 2020-09-12 04:00:00 |
| End Time: | 2020-09-12 10:00:00 |
| Description | The affected listed remained vailable as the provider Crown Castle performed circuit maintenance. The maintenance is complete. |
| AMPATH Nodes | Down Time | Reporting Period Availability | 52 Week Availability |
| BocaRaton-NE4-1-1 | 00 hr 00 min | 100.00000% | 100.00000% |
| j480.ampath.net | 00 hr 00 min | 100.00000% | 99.97393% |
| WS-Ai-MI3-1 | 00 hr 00 min | 100.00000% | 100.00000% |
| WS-Ai-MI1-1 | 00 hr 00 min | 100.00000% | 100.00000% |
| Miami-NE3-1-1 | 00 hr 00 min | 100.00000% | 100.00000% |
| j480-2.ampath.net | 00 hr 00 min | 100.00000% | 100.00000% |
| Aggregate AMPATH Core Nodes | 0 days 0 hr 0 min | 100.00000% | 99.99565% |
| AMPATH Backbone Circuits | Down Time | Reporting Period Availability | 52 Week Availability |
| FIU033WSA1SP4NN | 00 hr 00 min | 100.00000% | 98.73229% |
| FIU030WMI2FORNN | 00 hr 00 min | 100.00000% | 99.59760% |
| FIU034WFORSP4NN | 00 hr 00 min | 100.00000% | 99.33187% |
| FIU015TCARMI2NN | 00 hr 00 min | 100.00000% | 100.00000% |
| AMP-JACKSONVILLE-MIAMI-100GE-01503 | 00 hr 00 min | 100.00000% | 99.85446% |
| FIU026UMI2SA1NN | 0 hr 1 min | 99.99008% | 91.31473% |
| AMP-JACKSONVILLE-MIAMI-100GE-01502 | 00 hr 00 min | 100.00000% | 100.00000% |
| FIU031WCRPPANNN | 0 hr 0 min | 99.99024% | 99.87960% |
| FIU035WMI2CRPNN | 1 hr 13 min | 99.27100% | 99.25981% |
| FIU036WPANSA1NN | 00 hr 00 min | 100.00000% | 99.40272% |
| AMPATH-BOCA-MIAMI-DF | 6 hr 0 min | 96.42857% | 99.93188% |
| FIU020UMI2SP3NN | 00 hr 00 min | 100.00000% | 98.69360% |
| Aggregate All AMPATH Backbone Circuits | 0 days 7 hr 15 min | 99.63999% | 98.83321% |
| AMPATH Backbone Circuits | Down Time | Reporting Period Availability | 52 Week Availability |