SOX Network Operations Report
2018-04-01 - 2018-04-30

SOX Network Operations Center

New Connections

ConnectorTypeDateSponsor


Upgrades

None


New Services


None


Other


None


Unscheduled Outages Summary

Incident Number Customer Impact Network Impact Title Outage Type Source of Impact Current State Start Time (UTC) End Time (UTC)

INC0012799 3 - Moderate3 - Moderate Instability Resolved - SoX Participant CLIGHTUndetermined Undetermined Closed 2018-04-15 04:26:35 2018-04-16 20:40:59
INC0012709 3 - Moderate3 - Moderate Availability - SoX Participant CDCInvestigating Undetermined Closed 2018-04-09 07:38:24 2018-04-09 09:43:49

Unscheduled Outages Detail


Ticket No.:INC0012799
Subject:Instability Resolved - SoX Participant CLIGHT
Source Of Impact: Undetermined
Affected:SOX-56MAR-56MAR-10GE-01608
Participant CLIGHT
Current State:Closed
Start Time:2018-04-15 04:26:35
End Time:2018-04-16 20:40:59
DescriptionParticipant CLIGHT is now stable.. CLIGHT Engineers have been contacted and have confirmed that the instability was caused by a failing DC power inverter shelf.


Ticket No.:INC0012709
Subject:Availability - SoX Participant CDC
Source Of Impact: Undetermined
Affected:SOX-56MAR-56MAR-10GE-01715
SOX-56MAR-56MAR-VLAN-01717
Participant CDC
Current State:Closed
Start Time:2018-04-09 07:38:24
End Time:2018-04-09 09:43:49
DescriptionParticipant CDC is available. CDC Engineers have been contacted; however, the reason for the outage is pending.


Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Current State Start Time (UTC) End Time (UTC)

CHG00312273 - Moderate3 - Moderate Maintenance Completed - Sox Backbone SIDCO-SIDCO Circuit Vendor Closed 2018-04-16 11:50:002018-04-16 12:11:16

Scheduled Maintenances Detail


Ticket No.:CHG0031227
Subject:Maintenance Completed - Sox Backbone SIDCO-SIDCO
Source Of Impact: Vendor
Affected:SOX-SIDCO-SIDCO-10GE-01502
SOX-SIDCO-SIDCO-VLAN-01500
SOX-56MAR-SIDCO-VLAN-01506
Backbone SIDCO-SIDCO
Current State:Closed
Start Time:2018-04-16 11:50:00
End Time:2018-04-16 12:11:16
DescriptionBackbone SIDCO-SIDCO was unavailable while Peer MREN transitioned their connection to Internet2 to new hardware. A brief outage was observed during the maintenance window and maintenance has been completed.


Downtime and Availability



SOX NodesDown TimeReporting Period Availability52 Week Availability
rtr.akard.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
rtr.56mar.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
sw2.gtrch.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
sw1.55mar.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
dcp.sidco.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
sw1.56mar.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
rtr.imart.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
dcp.court.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
bbsw.56mar.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
rtr.mplex.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
dcp.mplex.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
mgmtsw.court.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
sw1.gtrch.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
rtr.sidco.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
mgmtsw.mplex.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
mgmtsw.sidco.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
sw2.56mar.sox.net00 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%

Aggregate SOX Core Nodes0 days 0 hr 0 min | 0 days 0 hr 0 min 100.00000% | 100.00000% 100.00000% | 100.00000%



NOTE: Numbers in italics represent downtime with scheduled maintenance excluded.



SOX Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
SOX-56MAR-56MAR-FE-0193500 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0182800 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-FE-0193800 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-MPLEX-MPLEX-FE-0195300 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0194600 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-FE-0194100 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-SIDCO-VLAN-015060 hr 21 min | 00 hr 00 min 99.95077% | 100.00000% 99.72274% | 100.00000%
SOX-56MAR-56MAR-VLAN-0166500 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-10GE-0189500 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-MPLEX-VLAN-0173100 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-COURT-COURT-GIGE-0195000 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-55MAR-56MAR-LAG-0189200 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0193400 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-IMART-56MAR-VLAN-0156200 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-10GE-0171800 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-FE-0194400 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-55MAR-55MAR-LAG-0189400 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-SIDCO-SIDCO-FE-0195900 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-COURT-COURT-GIGE-0195200 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0194800 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-MPLEX-SIDCO-VLAN-0153100 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-10GE-0177500 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-MPLEX-MPLEX-FE-0195400 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0194700 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-10GE-0171900 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-AKARD-AKARD-10GE-0156300 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-FE-0193700 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-LAG-0186200 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-55MAR-10GE-0188500 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-COURT-GIGE-0193000 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-COURT-GIGE-0192900 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-AKARD-IMART-VLAN-0154900 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-SIDCO-SIDCO-FE-0196200 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-MPLEX-SIDCO-VLAN-0150900 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-COURT-GIGE-0192800 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0193900 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-MPLEX-MPLEX-FE-0195500 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0194000 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-SIDCO-SIDCO-FE-0196100 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-MPLEX-MPLEX-FE-0195600 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-55MAR-56MAR-10GE-0196300 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-SIDCO-SIDCO-FE-0195800 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0183900 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0194500 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-COURT-GIGE-0192700 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-10GE-0174300 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-100GE-0166600 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-10GE-0193600 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-AKARD-56MAR-VLAN-0159000 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0193300 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-GTRCH-GIGE-0193100 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-FE-0194300 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-SIDCO-SIDCO-FE-0196000 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-MPLEX-MPLEX-FE-0195700 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-COURT-COURT-GIGE-0195100 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-AKARD-MPLEX-VLAN-0154100 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-MPLEX-56MAR-VLAN-0152200 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-55MAR-55MAR-LAG-0189300 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-55MAR-10GE-0173000 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-COURT-GIGE-0193200 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%
SOX-56MAR-56MAR-GIGE-0194900 hr 00 min | 00 hr 00 min 100.00000% | 100.00000% 100.00000% | 100.00000%

Aggregate All SOX Backbone Circuits0 days 0 hr 21 min |0 days 0 hr 0 min 99.99919% | 100.00000%99.99545% | 100.00000%



NOTE: Numbers in italics represent downtime with scheduled maintenance excluded.





Upcoming Scheduled Maintenances

Ticket No.:CHG0031243
Subject:Maintenance 3 of 3 - SoX Peer Internet2
Source Of Impact: Vendor
Affected:I2-MP-MP-VLAN-183932
Start Time:2018-05-09 03:00:00
End Time:2018-05-09 10:00:00
DescriptionPeer Internet2 will be unavailable while Zayo engineers perform splice case maintenance in Minneapolis, MN. Outages are expected throughout the maintenance window, and the entire window is reserved. This is the 3rd of 3 maintenance windows.


Ticket No.:CHG0031242
Subject:Maintenance 2 of 3 - SoX Peer Internet2
Source Of Impact: Vendor
Affected:I2-MP-MP-VLAN-183932
Start Time:2018-05-08 03:00:00
End Time:2018-05-08 10:00:00
DescriptionPeer Internet2 will be unavailable while Zayo engineers perform splice case maintenance in Minneapolis, MN. Outages are expected throughout the maintenance window, and the entire window is reserved. This is the 2nd of 3 maintenance windows.


Ticket No.:CHG0031221
Subject:Maintenance 2 of 3 - SoX Core Node 56MAR
Source Of Impact: Vendor
Affected:Subject: MAINTENANCE NOTIFICATION - INITIAL - MTST# 00500567 - ATL1 Date: Wed, 11 Apr 2018 19:33:10 -0400 From: Customer Notifications To: noc@sox.net April 11, 2018 *MAINTENANCE NOTIFICATION - INITIAL - MTST# 00500567 - ATL1* Valued Customer, Digital Realty engineering team has a scheduled maintenance as part of a Critical Load Redistribution project to increase maintainability and add an additional layer of redundancy to critical systems at our ATL13 (56 Marietta Street, Atlanta GA) facility. This project will be performed in three separate phases shown below. *Phase 1* - 4/28/2018 8:00AM – 4:00PM Prerequisite procedure to verify voltage readings while UPS 402 and UPS 5B1 are placed on bypass. During each bypass procedure customer load will not be protected by battery backup. All other steps associated with Phase 1 MOP should be seamless and non-service effecting. *Estimated total duration of critical work: 2 hrs.* *Phase 2* - 5/12/2018 - 8:00AM - 7:00PM Adding redundant power feeds to PDU402A, PDU 402B, PDU-52-1, PDU-52-2, PDU-52-3, PDU-53-3 and PDU-53-4. While the UPS bypass procedures are being performed (at the beginning and end of maintenance approximately 30 minutes each) each side of customer load will not be protected by UPS. All load supported by PDU 53-3 will be shut down. It is crucial that if customers subscribe to redundant power those customers verify the configuration and power consumption of customer equipment prior to this work so no unexpected preventable issues arise. As a prerequisite, Digital Realty has performed audits of all customers fed from this PDU and a _separate communication_ will be sent to those customers where we have identified non-redundant circuits or found equipment that we believe is not properly configured. *Estimated total duration of critical work: 11 hrs.* All other steps associated with Phase 2 MOP should be seamless and non-service affecting. *Phase 3* - 5/19/2018 - 8:00AM – 7:00PM Adding redundant power feeds PDU402A, PDU 402B, PDU-52-1, PDU-52-2, PDU-52-3, PDU-53-3 and PDU-53-4. While the UPS bypass procedures are being performed (at the beginning and en d of maintenance approximately 30 minutes each) each side of customer load will not be protected by UPS. All load supported by PDU 53-4 will be shut down. It is crucial that if customers subscribe to redundant power those customers verify the configuration and power consumption of your equipment prior to this work so no unexpected preventable issues arise. As a prerequisite, Digital Realty has performed audits of all customers fed from this PDU and a _separate communication_ will be sent to those customers where we have identified non-redundant circuits or found equipment that we believe is not properly configured. *Estimated total duration of critical work: 11 hrs.* All other steps associated with Phase 3 MOP should be seamless and non-service affecting. Maintenance TST# 00500567 Location: ATL1 (56 Marietta, Atlanta) Floor(s) / Suite(s): All Maintenance Type: Planned Maintenance Priority: YELLOW Event - PSA (Potentially Service Affecting) Product(s)/Asset(s) Affected: UPS Description: Critical Load Distribution Project Start Date/Time: 04/28/2018 08:00 AM EDT End Date/Time: 05/19/2018 07:00 PM EDT Duration: Please see phases above Related Work Orders: Related Circuit IDs: Please refer any questions to: The Global Command Center at gcc@digitalrealty.com or 888-835-9832
Start Time:2018-05-12 12:00:00
End Time:2018-05-12 23:00:00
DescriptionThe Core Node at 56 Marietta St. will remain available while Digital Realty Engineers perform power maintenance. No outages are expected during the maintenance window. The entire window is reserved. This is the 2nd of 3 windows.


Ticket No.:CHG0031241
Subject:Maintenance 1 of 3 - SoX Peer Internet2
Source Of Impact: Vendor
Affected:I2-MP-MP-VLAN-183932
Start Time:2018-05-07 03:00:00
End Time:2018-05-07 10:00:00
DescriptionPeer Internet2 will be unavailable while Zayo engineers perform splice case maintenance in Minneapolis, MN. Outages are expected throughout the maintenance window, and the entire window is reserved. This is the 1st of 3 maintenance windows.


Ticket No.:CHG0031222
Subject:Maintenance 3 of 3 - SoX Core Node 56MAR
Source Of Impact: Vendor
Affected:Subject: MAINTENANCE NOTIFICATION - INITIAL - MTST# 00500567 - ATL1 Date: Wed, 11 Apr 2018 19:33:10 -0400 From: Customer Notifications To: noc@sox.net April 11, 2018 *MAINTENANCE NOTIFICATION - INITIAL - MTST# 00500567 - ATL1* Valued Customer, Digital Realty engineering team has a scheduled maintenance as part of a Critical Load Redistribution project to increase maintainability and add an additional layer of redundancy to critical systems at our ATL13 (56 Marietta Street, Atlanta GA) facility. This project will be performed in three separate phases shown below. *Phase 1* - 4/28/2018 8:00AM – 4:00PM Prerequisite procedure to verify voltage readings while UPS 402 and UPS 5B1 are placed on bypass. During each bypass procedure customer load will not be protected by battery backup. All other steps associated with Phase 1 MOP should be seamless and non-service effecting. *Estimated total duration of critical work: 2 hrs.* *Phase 2* - 5/12/2018 - 8:00AM - 7:00PM Adding redundant power feeds to PDU402A, PDU 402B, PDU-52-1, PDU-52-2, PDU-52-3, PDU-53-3 and PDU-53-4. While the UPS bypass procedures are being performed (at the beginning and end of maintenance approximately 30 minutes each) each side of customer load will not be protected by UPS. All load supported by PDU 53-3 will be shut down. It is crucial that if customers subscribe to redundant power those customers verify the configuration and power consumption of customer equipment prior to this work so no unexpected preventable issues arise. As a prerequisite, Digital Realty has performed audits of all customers fed from this PDU and a _separate communication_ will be sent to those customers where we have identified non-redundant circuits or found equipment that we believe is not properly configured. *Estimated total duration of critical work: 11 hrs.* All other steps associated with Phase 2 MOP should be seamless and non-service affecting. *Phase 3* - 5/19/2018 - 8:00AM – 7:00PM Adding redundant power feeds PDU402A, PDU 402B, PDU-52-1, PDU-52-2, PDU-52-3, PDU-53-3 and PDU-53-4. While the UPS bypass procedures are being performed (at the beginning and en d of maintenance approximately 30 minutes each) each side of customer load will not be protected by UPS. All load supported by PDU 53-4 will be shut down. It is crucial that if customers subscribe to redundant power those customers verify the configuration and power consumption of your equipment prior to this work so no unexpected preventable issues arise. As a prerequisite, Digital Realty has performed audits of all customers fed from this PDU and a _separate communication_ will be sent to those customers where we have identified non-redundant circuits or found equipment that we believe is not properly configured. *Estimated total duration of critical work: 11 hrs.* All other steps associated with Phase 3 MOP should be seamless and non-service affecting. Maintenance TST# 00500567 Location: ATL1 (56 Marietta, Atlanta) Floor(s) / Suite(s): All Maintenance Type: Planned Maintenance Priority: YELLOW Event - PSA (Potentially Service Affecting) Product(s)/Asset(s) Affected: UPS Description: Critical Load Distribution Project Start Date/Time: 04/28/2018 08:00 AM EDT End Date/Time: 05/19/2018 07:00 PM EDT Duration: Please see phases above Related Work Orders: Related Circuit IDs: Please refer any questions to: The Global Command Center at gcc@digitalrealty.com or 888-835-9832
Start Time:2018-05-19 12:00:00
End Time:2018-05-19 23:00:00
DescriptionThe Core Node at 56 Marietta St. will remain available while Digital Realty Engineers perform power maintenance. No outages are expected during the maintenance window. The entire window is reserved. This is the 3rd of 3 windows.


Ticket No.:CHG0031286
Subject:Maintenance - SoX Backbone 56MAR-SIDCO
Source Of Impact: Vendor
Affected:Georgia Tech BCDC (SOX-56MAR-56MAR-100GE-01774) Georgia Tech Rich (SOX-56MAR-56MAR-100GE-02080) Internet2 AL2S port (SOX-56MAR-56MAR-100GE-01666) FLR (SOX-56MAR-56MAR-100GE-02114) Vanderbilt (SOX-56MAR-56MAR-100GE-02013) ESnet (SOX-56MAR-56MAR-100GE-02019) UAB (SOX-56MAR-56MAR-100GE-02037) rtr.sidco (SOX-56MAR-SIDCO-100GE-02045)
Start Time:2018-05-09 08:00:00
End Time:2018-05-09 10:00:00
DescriptionThe backbone circuit between 56 Marietta and Nashville (SIDCO) will be unavailable while Southern Crossroads Engineering perform maintenance to replace two MPC7 linecards at 56 Marietta. The listed Peer and Participant connections will be impacted during the maintenance window. The Georgia Tech Rich connection will be moved at the beginning of the maintenance to blade 5 in order to maintain one of the two Georgia Tech connections throughout the maintenance. The entire window is reserved.


Ticket No.:CHG0031244
Subject:Maintenance 3 of 3 - SoX Peer Internet2
Source Of Impact: Vendor
Affected:I2-MP-MP-VLAN-183932
Start Time:2018-05-08 03:00:00
End Time:2018-05-08 10:00:00
DescriptionPeer Internet2 will be unavailable while Zayo engineers perform splice case maintenance in Minneapolis, MN. Outages are expected throughout the maintenance window, and the entire window is reserved. This is the 3rd of 3 maintenance windows.