Indiana GigaPOP Network Operations Report
2020-01-10 - 2020-01-23

Indiana GigaPOP Network Operations Center

Unscheduled Outages Summary

Incident Number Customer Impact Network Impact Title Outage Type Source of Impact Current State Start Time (UTC) End Time (UTC) Duration


Unscheduled Outages Detail


None during this report period


Upcoming Scheduled Maintenances

Ticket No.:CHG0040664
Subject:Maintenance Completed - Indiana GigaPOP Internal Prep Work Backup RE Upgrade (ICTC, CHIC, and LL)
Source Of Impact: Internal
Affected:
Start Time:2020-01-27 17:00:00
End Time:2020-01-28 11:00:00
DescriptionIndiana GigaPOP Engineering performed maintenance to conduct prep work prior to the maintenance window (CHG0040610) to upgrade the backup REs on ICTC, CHIC, and LL. Maintenance has been completed.


Ticket No.:CHG0040571
Subject:Maintenance 1 of 3 - Indiana GigaPOP POP Lifeline
Source Of Impact: Vendor
Affected:POP Lifeline
Start Time:2020-02-24 13:00:00
End Time:2020-02-24 22:00:00
DescriptionStarting Monday, February 24, 2020 through Wednesday, February 26, 2020 beginning at 8:00AM ET and ending at approximately 5:00PM ET each day, Lifeline Data Centers and Mitsubishi Engineers will be performing scheduled mandatory, major preventive maintenance inspections on all 9 UPS systems at the 401 North Shadeland Avenue facility and all 4 UPS systems at the 733 West Henry Street facility. The major inspection routine dictates that the UPS systems be placed in external bypass as part of the service. External bypass is an OSHA and arc flash safety requirement due to the close proximity of live 480-volt power to some of the work being performed. External bypass is a manual process which externally wraps power around the UPS system. Should a utility power failure occur while the UPS system is bypassed, the power feed will be protected by generator only. Some important notes regarding the procedure: - The external bypass procedure is electrically a make-before-break process. This means that the power feed to the output side of the UPS system will not be interrupted by the wraparound procedure or at any time during the process. - Each unit will be in external bypass mode for about 1 hour. - Only 1 unit at each facility will be in external bypass mode at any given time. *Please note - This is maintenance window 1 of 3. The second activity date is scheduled for Tuesday, February 25, 2020. the third activity date is scheduled for Wednesday, February, 26, 2020.


Ticket No.:CHG0040657
Subject:Maintenance - Indiana GigaPOP Peer University of Illinois at Urbana-Champaign and Peer University of Iowa
Source Of Impact: Vendor
Affected:Peer University of Illinois at Urbana-Champaign
Peer University of Iowa
Start Time:2020-01-29 06:00:00
End Time:2020-01-29 12:00:00
DescriptionPeer University of Illinois at Urbana-Champaign and Peer University of Iowa will be unavailable while Vendor CenturyLink Engineers perform maintenance. An outage of up to one (1) hour is expected; however, the entire window is reserved. Please note - Traffic will reroute via redundant connections.


Ticket No.:CHG0040782
Subject:Maintenance - Indiana GigaPOP Peer Education Networks of America
Source Of Impact: Internal
Affected:Peer Education Networks of America
Start Time:2020-02-02 10:00:00
End Time:2020-02-02 11:00:00
DescriptionIndiana GigaPOP Engineers will be performing maintenance to enable peering to Education Networks of America (AS11686). No outages are expected; however, the entire maintenance window is reserved.


Ticket No.:CHG0040783
Subject:Maintenance - Indiana GigaPOP Internal NetFlow Sampling Rate Change
Source Of Impact: Internal
Affected:
Start Time:2020-02-02 10:00:00
End Time:2020-02-02 11:00:00
DescriptionIndiana GigaPOP Engineers will be performing maintenance to adjust the NetFlow Sampling Rate, from 100 to 50. No outages are expected; however, the entire window is reserved.


Ticket No.:CHG0040573
Subject:Maintenance 3 of 3 - Indiana GigaPOP POP Lifeline
Source Of Impact: Vendor
Affected:POP Lifeline
Start Time:2020-02-26 13:00:00
End Time:2020-02-26 22:00:00
DescriptionStarting Monday, February 24, 2020 through Wednesday, February 26, 2020 beginning at 8:00AM ET and ending at approximately 5:00PM ET each day, Lifeline Data Centers and Mitsubishi Engineers will be performing scheduled mandatory, major preventive maintenance inspections on all 9 UPS systems at the 401 North Shadeland Avenue facility and all 4 UPS systems at the 733 West Henry Street facility. The major inspection routine dictates that the UPS systems be placed in external bypass as part of the service. External bypass is an OSHA and arc flash safety requirement due to the close proximity of live 480-volt power to some of the work being performed. External bypass is a manual process which externally wraps power around the UPS system. Should a utility power failure occur while the UPS system is bypassed, the power feed will be protected by generator only. Some important notes regarding the procedure: - The external bypass procedure is electrically a make-before-break process. This means that the power feed to the output side of the UPS system will not be interrupted by the wraparound procedure or at any time during the process. - Each unit will be in external bypass mode for about 1 hour. - Only 1 unit at each facility will be in external bypass mode at any given time. *Please note - This is maintenance window 3 of 3.


Ticket No.:CHG0040572
Subject:Maintenance 2 of 3 - Indiana GigaPOP POP Lifeline
Source Of Impact: Vendor
Affected:POP Lifeline
Start Time:2020-02-25 13:00:00
End Time:2020-02-25 22:00:00
DescriptionStarting Monday, February 24, 2020 through Wednesday, February 26, 2020 beginning at 8:00AM ET and ending at approximately 5:00PM ET each day, Lifeline Data Centers and Mitsubishi Engineers will be performing scheduled mandatory, major preventive maintenance inspections on all 9 UPS systems at the 401 North Shadeland Avenue facility and all 4 UPS systems at the 733 West Henry Street facility. The major inspection routine dictates that the UPS systems be placed in external bypass as part of the service. External bypass is an OSHA and arc flash safety requirement due to the close proximity of live 480-volt power to some of the work being performed. External bypass is a manual process which externally wraps power around the UPS system. Should a utility power failure occur while the UPS system is bypassed, the power feed will be protected by generator only. Some important notes regarding the procedure: - The external bypass procedure is electrically a make-before-break process. This means that the power feed to the output side of the UPS system will not be interrupted by the wraparound procedure or at any time during the process. - Each unit will be in external bypass mode for about 1 hour. - Only 1 unit at each facility will be in external bypass mode at any given time. *Please note - This is maintenance window 2 of 3. The third activity date is scheduled for Wednesday, February, 26, 2020.


Ticket No.:CHG0040785
Subject:Maintenance - Indiana GigaPOP Various Peers
Source Of Impact: Vendor
Affected:Peer University of Iowa
Peer University of Minnesota - Twin Cities
Peer University of Wisconsin at Madison
Start Time:2020-02-05 06:01:00
End Time:2020-02-05 12:00:00
DescriptionThe listed Peers will be unavailable while Boreas Engineers perform fiber maintenance. Outages are expected and the entire window is reserved.


Ticket No.:CHG0040610
Subject:Maintenance Completed - Indiana GigaPOP Core Routers CHIC, LL, and ICTC
Source Of Impact: Internal
Affected:Backbone PURESEARCH-LL
Backbone LL-LL
Backbone ICTC-LL
Backbone CHIC-LL
Backbone BLDC-LL
Backbone ILN-ING
Member Purdue Research
Member Purdue University
Member St. Louis Internet2 Access Consortium (WUSTL)
Member NCAA
Memebr Indiana Office of Technology
Member Indianapolis Zoo
Member IU Research Network
Member IU Research Network Operations
Member Indiana University
Member CSPAN
Member University of Notre Dame
Member Wabash College
Member BTAA OmniPoP
Peer University of Chicago
Peer Mid West Tier 2 Admins
Peer University of Wisconsin at Madison
Peer University of Minnesota - Twin Cities
Peer OARnet
Peer FutureGrid
Peer University of Illinois at Urbana-Champaign
Peer I-Light
Peer Wintek Corporation
Peer Big Ten Academic Alliance
Peer Internet2
Peer N-Wave
Start Time:2020-01-28 05:00:00
End Time:2020-01-28 11:00:00
DescriptionIndiana GigaPOP Network Engineers performed maintenance to upgrade software on Core Routers CHIC, LL, and ICTC. Routers were upgraded one (1) at a time in order to minimize impact to Members. Maintenance is completed.