I-Light Network Operations Report
2019-01-25 - 2019-02-07

I-Light Network Operations Center

Unscheduled Outages Summary

Incident Number Customer Impact Network Impact Title Outage Type Source of Impact Current State Start Time (UTC) End Time (UTC)

INC0027799 2 - High2 - High Outage Resolved - I-Light Backbone ARSN-IPHECircuit - Damaged Fiber Vendor Resolved 2019-01-30 10:42:32 2019-01-30 22:22:53

Unscheduled Outages Detail


Ticket No.:INC0027799
Subject:Outage Resolved - I-Light Backbone ARSN-IPHE
Source Of Impact: Vendor
Affected:ILN-ARSN-IPHE-FIBR-23956
Backbone IPHE-ARSN
Member Anderson University
Member Ball State University
Member Ball State University Fishers
Member Ball State University Learning Center
Member Bethel College
Member Calumet College of Saint Joseph
Member Goshen College
Member Grace College
Member Holy Cross College
Member Huntington University
Member IU Foundation
Member Indiana Institute of Technology Ft. Wayne
Member Indiana Office of Technology
Member Indiana University Kokomo
Member Indiana University Northwest
Member Indiana University Purdue University Ft. Wayne
Member Indiana University South Bend
Member Indiana Wesleyan University
Member Ivy Tech East Chicago
Member Ivy Tech Elkhart
Member Ivy Tech Fort Wayne
Member Ivy Tech Gary
Member Ivy Tech Kokomo
Member Ivy Tech Lafayette
Member Ivy Tech Marion
Member Ivy Tech Michigan City
Member Ivy Tech Monticello
Member Ivy Tech Muncie
Member Ivy Tech Northwest
Member Ivy Tech South Bend
Member Ivy Tech Valparaiso
Member Ivy Tech Warsaw
Member Manchester University - North Manchester Campus
Member Purdue NorthWest Hammond Campus
Member Purdue University Anderson
Member St. Francis Crown Point
Member St. Mary of the Woods College
Member Taylor University
Member Trine University
Member University of Notre Dame
Member WNIT - Michiana Public Broadcasting Corporation
Member Wabash College
Current State:Resolved
Start Time:2019-01-30 10:42:32
End Time:2019-01-30 22:22:53
DescriptionBackbone ARSN-IPHE is now available. Zayo dispatched an OSP crew and identified a frozen handheld. The handheld was thawed and revealed fiber damage from animal chewing. The fiber has been repaired and crews are hands off. No further outages are expected.




Upcoming Scheduled Maintenances

Ticket No.:CHG0034886
Subject:Maintenance 2 of 2 Completed - I-Light Various Backbones
Source Of Impact: Vendor
Affected:Backbone IPIU-SBND
Backbone IPHE-IPIU
Backbone GARY-SBND
Backbone GARY-MCCI
Backbone PUNC-VALP
Member Anderson University
Member Ball State University
Member Ball State University Fishers
Member Ball State University Learning Center
Member Bethel College
Member Calumet College of Saint Joseph
Member Earlham College
Member Goshen College
Member Grace College
Member Holy Cross College
Member Huntington University
Member IU Foundation
Member Indiana Institute of Technology Ft. Wayne
Member Indiana Office of Technology
Member Indiana University Northwest
Member Indiana University South Bend
Member Indiana University Purdue University Ft. Wayne
Member Indiana Wesleyan University
Member Ivy Tech Connersville
Member Ivy Tech East Chicago
Member Ivy Tech Elkhart
Member Ivy Tech Fort Wayne
Member Ivy Tech Gary
Member Ivy Tech Indianapolis Central Office
Member Ivy Tech Lafayette
Member Ivy Tech Lawrenceburg
Member Ivy Tech Marion
Member Ivy Tech Michigan City
Member Ivy Tech Monticello
Member Ivy Tech Muncie
Member Ivy Tech Northwest
Member Ivy Tech Richmond
Member Ivy Tech Valparaiso
Member Ivy Tech Warsaw
Member Manchester University - Ft. Wayne Campus
Member Manchester University - North Manchester Campus
Member Purdue NorthWest Hammond Campus
Member Purdue University Anderson
Member Taylor University
Member Trine University
Member University of Notre Dame
Member WNIT - Michiana Public Broadcasting Corporation
Member Wabash College
Start Time:2019-02-08 06:00:00
End Time:2019-02-08 12:00:00
DescriptionThe above listed were unavailable while Zayo Engineers performed maintenance to bore new ducts south 600 feet under the new creek culvert and set a new hand hole to intercept the existing ducts. Outages occurred and this maintenance has been completed. *Please note - All traffic rerouted via redundant connections. *This was maintenance window 2 of 2*


Ticket No.:CHG0034673
Subject:Maintenance 2 of 2 - I-Light Member Ivy Tech Fairbanks
Source Of Impact: Internal
Affected:Member Ivy Tech Fairbanks
Start Time:2019-02-12 05:00:00
End Time:2019-02-12 11:00:00
DescriptionI-Light Engineers will be performing maintenance on the Ivy Tech Fairbanks connection. Brief outages are expected throughout the duration of the window. The entire window is reserved. Please note - This is maintenance window 2 of 2.


Ticket No.:CHG0034764
Subject:Maintenance - I-Light Backbone GNCS-IPHE
Source Of Impact: Internal
Affected:Backbone GNCS-IPHE
Backbone IPHE-VINC
Member Oakland City University
Member Indiana State University
Member University of Evansville
Member Vincennes University Aviation
Member Vincennes University - Jasper
Member Vincennes University Lebanon
Member Vincennes University - Plainfield
Member Vincennes University - Fort Branch
Member Vincennes University - Indiana Deaf School
Member St. Mary of the Woods College
Member University of Southern Indiana
Member Hanover College
Member Ivy Tech Evansville
Member Ivy Tech Sellersburg
Member Ivy Tech Madison
Member Ivy Tech Indianapolis Central Office
Member Rose Hulman Institute of Technology
Member Rose Hulman Venture
Member Wabash College
Member WFWA - Fort Wayne
Member Indiana University Southeast
Start Time:2019-02-13 05:00:00
End Time:2019-02-13 11:00:00
DescriptionI-Light Engineers will be working on the GNCS-IPHE span. Outages are expected but members will reroute via redundant path. The entire window is reserved.


Ticket No.:CHG0034538
Subject:Maintenance - I-Light Member Indiana University Research OPS Provisioning
Source Of Impact: Internal
Affected:Member Indiana University Research
Start Time:2019-02-10 12:00:00
End Time:2019-02-10 13:00:00
DescriptionI-Light Engineers will be working with Member Indiana University Research Engineers to amend OPS parameters for the 100GE circuit between IUPUI and IUB. An outage of thirty (30) to sixty (60) minutes is expected, however the entire maintenance window is reserved.