AMPATH Network Operations Report
2020-08-03 - 2020-08-09

AMPATH Network Operations Center

New Connections

ConnectorTypeDateSponsor


Upgrades

None


New Services


None


Other


None


Unscheduled Outages Summary

Incident Number Customer Impact Network Impact Title Outage Type Source of Impact Current State Start Time (UTC) End Time (UTC) Duration

INC0062352 4 - Low2 - High Brief Outage Resolved - AMPATH Provider LANautilus FIU034WFORSP4NNUndetermined Vendor Closed 2020-08-03 18:12:00 2020-08-03 18:13:00 0 days 0 hr 1 min
INC0062511 4 - Low2 - High Brief Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NNCircuit - Bumped Fiber Vendor Closed 2020-08-05 16:17:00 2020-08-05 16:18:00 0 days 0 hr 1 min
INC0062504 2 - High2 - High Outage Update - AMPATH Provider LANautilus FIU033WSA1SP4NNCircuit - Damaged Fiber Vendor Closed 2020-08-05 14:49:00 2020-08-05 22:02:44 0 days 7 hr 13 min
INC0062581 4 - Low2 - High Brief Outage Resolved - AMPATH LANautilus Circuit FIU030WMI2FORNNCircuit - Other Vendor Closed 2020-08-06 12:08:35 2020-08-06 12:08:36 0 days 0 hr 0 min
INC0062664 2 - High2 - High Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NNInvestigating Vendor Closed 2020-08-07 08:05:15 2020-08-07 13:55:31 0 days 5 hr 50 min
INC0062700 2 - High2 - High Brief Outage - AMPATH LANautilus Circuit FIU030WMI2FORNNCircuit - Other Vendor Closed 2020-08-07 19:54:11 2020-08-07 19:54:12 0 days 0 hr 0 min
INC0062701 2 - High2 - High Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NNInvestigating Vendor Closed 2020-08-07 20:40:42 2020-08-08 00:48:00 0 days 4 hr 7 min

Unscheduled Outages Detail


Ticket No.:INC0062352
Subject:Brief Outage Resolved - AMPATH Provider LANautilus FIU034WFORSP4NN
Source Of Impact: Vendor
Affected:FIU034WFORSP4NN
Current State:Closed
Start Time:2020-08-03 18:12:00
End Time:2020-08-03 18:13:00
DescriptionThe listed asset is available following a brief outage. AMPATH and LANautilus Engineers have been contacted. The reason for the outage is undetermined. No further outages are expected.


Ticket No.:INC0062511
Subject:Brief Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN
Source Of Impact: Vendor
Affected:FIU026UMI2SA1NN
Current State:Closed
Start Time:2020-08-05 16:17:00
End Time:2020-08-05 16:18:00
DescriptionThe listed asset is available following a brief outage. AMPATH and LANautilus Engineers have been contacted and identified a brief oscillation in Panama. Connectivity has restored and no further events are expected.


Ticket No.:INC0062504
Subject:Outage Update - AMPATH Provider LANautilus FIU033WSA1SP4NN
Source Of Impact: Vendor
Affected:FIU033WSA1SP4NN
Current State:Closed
Start Time:2020-08-05 14:49:00
End Time:2020-08-05 22:02:44
DescriptionThe listed asset is unavailable. LANautilus Engineers have been contacted and identified a possible fiber event in Córdoba, Argentina. The fiber has been repair. No further outages are expected.


Ticket No.:INC0062581
Subject:Brief Outage Resolved - AMPATH LANautilus Circuit FIU030WMI2FORNN
Source Of Impact: Vendor
Affected:FIU030WMI2FORNN
Current State:Closed
Start Time:2020-08-06 12:08:35
End Time:2020-08-06 12:08:36
DescriptionLANautilus Circuit FIU030WMI2FORNN is available following a brief outage. LANautilus Engineers have reported the outage was caused by a network event in St. Croix


Ticket No.:INC0062664
Subject:Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NN
Source Of Impact: Vendor
Affected:FIU020UMI2SP3NN
Current State:Closed
Start Time:2020-08-07 08:05:15
End Time:2020-08-07 13:55:31
DescriptionThe following assets are available. LANautilus engineers identified the reason for the outage as a fiber event in Carapicuíba, Brazil. Service has restored and no further outages are expected.


Ticket No.:INC0062700
Subject:Brief Outage - AMPATH LANautilus Circuit FIU030WMI2FORNN
Source Of Impact: Vendor
Affected:FIU030WMI2FORNN
Current State:Closed
Start Time:2020-08-07 19:54:11
End Time:2020-08-07 19:54:12
DescriptionThe listed assets are available following a brief outage. LANautlius Engineers have been contacted. The reason for outage is a protection switch caused by a brief oscillation between St. Croix and Miami.


Ticket No.:INC0062701
Subject:Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NN
Source Of Impact: Vendor
Affected:FIU020UMI2SP3NN
Current State:Closed
Start Time:2020-08-07 20:40:42
End Time:2020-08-08 00:48:00
DescriptionThe listed asset is unavailable. LANautilus Engineers have been contacted. The reason for the outage is a fiber cut in one of ours backhauls in Sao Paulo, Brazil. Caused by a truck with high load. No further outages are expected.


Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Current State Start Time (UTC) End Time (UTC) Duration


Scheduled Maintenances Detail


None during this report period

Downtime and Availability



AMPATH NodesDown TimeReporting Period Availability52 Week Availability
BocaRaton-NE4-1-100 hr 00 min100.00000% 100.00000%
j480.ampath.net00 hr 00 min100.00000% 99.97393%
WS-Ai-MI3-100 hr 00 min100.00000% 100.00000%
WS-Ai-MI1-100 hr 00 min100.00000% 100.00000%
Miami-NE3-1-100 hr 00 min100.00000% 100.00000%
j480-2.ampath.net00 hr 00 min100.00000% 100.00000%

Aggregate AMPATH Core Nodes0 days 0 hr 0 min 100.00000% 99.99565%

AMPATH Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
FIU033WSA1SP4NN7 hr 13 min 95.69708% 98.66492%
FIU030WMI2FORNN0 hr 0 min 99.99967% 99.59801%
AMP-JACK-JACK-100GE-5241100 hr 00 min 100.00000% 98.40019%
FIU034WFORSP4NN0 hr 1 min 99.99008% 99.26655%
FIU015TCARMI2NN00 hr 00 min 100.00000% 100.00000%
FIU026UMI2SA1NN0 hr 1 min 99.99008% 91.34747%
FIU031WCRPPANNN00 hr 00 min 100.00000% 99.87999%
FIU035WMI2CRPNN00 hr 00 min 100.00000% 99.64023%
FIU036WPANSA1NN00 hr 00 min 100.00000% 99.41554%
AMPATH-BOCA-MIAMI-DF00 hr 00 min 100.00000% 100.00000%
FIU020UMI2SP3NN9 hr 57 min 94.07175% 98.14361%

Aggregate All AMPATH Backbone Circuits0 days 17 hr 13 min 99.06806% 98.57786%

Availablity by Service

AMPATH Backbone CircuitsDown TimeReporting Period Availability52 Week Availability


Upcoming Scheduled Maintenances

None Currently Planned