AMPATH Network Operations Report
2020-06-15 - 2020-06-21

AMPATH Network Operations Center

New Connections

ConnectorTypeDateSponsor


Upgrades

None


New Services


None


Other


None


Unscheduled Outages Summary

Incident Number Customer Impact Network Impact Title Outage Type Source of Impact Current State Start Time (UTC) End Time (UTC) Duration

INC0059281 2 - High2 - High Outage Resolved - AMPATH Provider LANautilus FIU034WFORSP4NNCircuit - Damaged Fiber Vendor Closed 2020-06-15 14:32:06 2020-06-16 03:11:00 0 days 12 hr 38 min
INC0059304 4 - Low2 - High Brief Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NNCircuit - Other Vendor Resolved 2020-06-16 01:59:00 2020-06-16 01:59:18 0 days 0 hr 0 min
INC0059313 2 - High2 - High Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NNCircuit - Cut Fiber Vendor Closed 2020-06-16 05:56:30 2020-06-16 12:34:00 0 days 6 hr 37 min
INC0059419 2 - High2 - High Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NNUnannounced Maintenance Vendor Closed 2020-06-18 04:11:42 2020-06-18 06:58:18 0 days 2 hr 46 min

Unscheduled Outages Detail


Ticket No.:INC0059281
Subject:Outage Resolved - AMPATH Provider LANautilus FIU034WFORSP4NN
Source Of Impact: Vendor
Affected:FIU034WFORSP4NN
Current State:Closed
Start Time:2020-06-15 14:32:06
End Time:2020-06-16 03:11:00
DescriptionThe listed asset is now available. AMPATH and LANautilus Engineers have been contacted. The reason for the outage was a degraded fiber in the submarine system in Rio, Brazil. Repairs have been completed. No further outages are expected.


Ticket No.:INC0059304
Subject:Brief Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NN
Source Of Impact: Vendor
Affected:FIU020UMI2SP3NN
Current State:Resolved
Start Time:2020-06-16 01:59:00
End Time:2020-06-16 01:59:18
DescriptionThe listed asset is currently available following a brief outage. Lanautilus engineers have been contacted. The reason for outage is due to a degraded path. No further outages is expected.


Ticket No.:INC0059313
Subject:Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN
Source Of Impact: Vendor
Affected:FIU026UMI2SA1NN
Current State:Closed
Start Time:2020-06-16 05:56:30
End Time:2020-06-16 12:34:00
DescriptionThe listed asset is available. LANautilus Engineers have been contacted. The reason for the outage is a fiber cut in Chile. The fiber has been restored and outages resolved. No further impact is expected.


Ticket No.:INC0059419
Subject:Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN
Source Of Impact: Vendor
Affected:FIU026UMI2SA1NN
Current State:Closed
Start Time:2020-06-18 04:11:42
End Time:2020-06-18 06:58:18
DescriptionThe following asset is available. LAnautilus engineers have determined the reason for the outage is due to scheduled maintenance. The maintenance is now complete. No further outages are expected


Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Current State Start Time (UTC) End Time (UTC) Duration

CHG0043134 Maintenance Completed - AMPATH Backbone JACK-JACK Circuit Vendor Closed 2020-06-19 04:00:152020-06-19 06:36:07 0 days 2 hr 35 min

Scheduled Maintenances Detail


Ticket No.:CHG0043134
Subject:Maintenance Completed - AMPATH Backbone JACK-JACK
Source Of Impact: Vendor
Affected:AMP-JACK-JACK-100GE-52411
Backbone JACK-JACK
Current State:Closed
Start Time:2020-06-19 04:00:15
End Time:2020-06-19 06:36:07
DescriptionThe following assets are now available after Vendor engineers performed maintenance on a backbone cable between Orlando, FL and Jacksonville, FL. The maintenance is now complete. No further outages are expected.


Downtime and Availability



AMPATH NodesDown TimeReporting Period Availability52 Week Availability
BocaRaton-NE4-1-100 hr 00 min100.00000% 100.00000%
j480.ampath.net00 hr 00 min100.00000% 99.95629%
WS-Ai-MI3-100 hr 00 min100.00000% 100.00000%
WS-Ai-MI1-100 hr 00 min100.00000% 100.00000%
Miami-NE3-1-100 hr 00 min100.00000% 100.00000%
j480-2.ampath.net00 hr 00 min100.00000% 100.00000%

Aggregate AMPATH Core Nodes0 days 0 hr 0 min 100.00000% 99.99271%

AMPATH Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
FIU033WSA1SP4NN00 hr 00 min 100.00000% 98.37164%
FIU030WMI2FORNN00 hr 00 min 100.00000% 99.59805%
AMP-JACK-JACK-100GE-524112 hr 35 min 98.45370% 98.25186%
FIU034WFORSP4NN12 hr 38 min 92.47122% 99.35264%
FIU015TCARMI2NN00 hr 00 min 100.00000% 100.00000%
FIU026UMI2SA1NN9 hr 24 min 94.40376% 91.53799%
FIU031WCRPPANNN00 hr 00 min 100.00000% 99.87999%
FIU035WMI2CRPNN00 hr 00 min 100.00000% 99.33692%
FIU036WPANSA1NN00 hr 00 min 100.00000% 99.29498%
FIU020UMI2SP3NN0 hr 0 min 99.99702% 98.22223%

Aggregate All AMPATH Backbone Circuits1 days 0 hr 39 min 98.53257% 98.38463%

Availablity by Service

AMPATH Backbone CircuitsDown TimeReporting Period Availability52 Week Availability


Upcoming Scheduled Maintenances

Ticket No.:CHG0043428
Subject:Maintenance Completed - AMPATH Provider LANautilus FIU033WSA1SP4NN
Source Of Impact: Vendor
Affected:FIU033WSA1SP4NN
Start Time:2020-06-22 09:00:00
End Time:2020-06-22 09:30:00
DescriptionThe following asset was not impacted while AMLight engineers performed maintenance. Maintenance is complete.