AMPATH Network Operations Report
2020-01-13 - 2020-01-19
AMPATH Network Operations Center
Connector | Type | Date | Sponsor |
---|
None
None
None
Incident Number | Customer Impact | Network Impact | Title | Outage Type | Source of Impact | Current State | Start Time (UTC) | End Time (UTC) | Duration |
---|---|---|---|---|---|---|---|---|---|
INC0049685 | 2 - High | 2 - High | Outage Resolved - AMPATH Backbone Circuit AMP-JACK-JACK-100GE-52411 | Circuit - Cut Fiber | Vendor | Resolved | 2020-01-13 20:29:00 | 2020-01-14 07:04:00 | 0 days 10 hr 35 min |
INC0049692 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU034WFORSP4NN | Undetermined | Vendor | Resolved | 2020-01-13 21:25:00 | 2020-01-13 21:26:00 | 0 days 0 hr 1 min |
INC0049702 | 2 - High | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN | Circuit - Cut Fiber | Vendor | Closed | 2020-01-13 23:29:00 | 2020-01-14 06:14:00 | 0 days 6 hr 45 min |
INC0049712 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU034WFORSP4NN and FIU033WSA1SP4NN | Undetermined | Vendor | Resolved | 2020-01-14 02:55:21 | 2020-01-14 02:56:57 | 0 days 0 hr 1 min |
INC0049741 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU034WFORSP4NN | Undetermined | Vendor | Closed | 2020-01-14 14:27:00 | 2020-01-14 14:28:00 | 0 days 0 hr 1 min |
INC0049782 | 2 - High | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN | Circuit - Cut Fiber | Vendor | Resolved | 2020-01-15 05:14:41 | 2020-01-15 10:49:16 | 0 days 5 hr 34 min |
INC0049815 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU033WSA1SP4NN & FIU034WFORSP4NN | Undetermined | Vendor | Closed | 2020-01-15 14:21:00 | 2020-01-15 14:22:00 | 0 days 0 hr 1 min |
INC0049850 | 2 - High | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN | Hardware | Vendor | Closed | 2020-01-15 22:07:58 | 2020-01-16 07:09:00 | 0 days 9 hr 1 min |
INC0049885 | 4 - Low | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN | Hardware | Vendor | Resolved | 2020-01-16 11:46:15 | 2020-01-16 12:54:07 | 0 days 1 hr 7 min |
INC0049899 | 4 - Low | 2 - High | Brief Outage Resolved - AMPATH Provider LANautilus FIU030WMI2FORNN | Undetermined | Vendor | Resolved | 2020-01-16 15:16:23 | 2020-01-16 15:16:24 | 0 days 0 hr 0 min |
INC0049994 | 2 - High | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN | Hardware | Vendor | Resolved | 2020-01-17 16:46:53 | 2020-01-17 18:07:21 | 0 days 1 hr 20 min |
INC0050035 | 4 - Low | 2 - High | Brief Outage - AMPATH LANautilus Circuit FIU034WFORSP4NN | Undetermined | Vendor | Resolved | 2020-01-18 08:01:03 | 2020-01-18 08:01:04 | 0 days 0 hr 0 min |
Ticket No.: | INC0049685 |
Subject: | Outage Resolved - AMPATH Backbone Circuit AMP-JACK-JACK-100GE-52411 |
Source Of Impact: | Vendor |
Affected: | AMP-JACK-JACK-100GE-52411 |
Current State: | Resolved |
Start Time: | 2020-01-13 20:29:00 |
End Time: | 2020-01-14 07:04:00 |
Description | The listed asset is now available. FIU Engineers have been contacted. The reason for the outage was a fiber cut. Repairs have been completed. No further outages are expected. |
Ticket No.: | INC0049692 |
Subject: | Brief Outage - AMPATH Provider LANautilus FIU034WFORSP4NN |
Source Of Impact: | Vendor |
Affected: | FIU034WFORSP4NN |
Current State: | Resolved |
Start Time: | 2020-01-13 21:25:00 |
End Time: | 2020-01-13 21:26:00 |
Description | The listed asset is available following a brief outage. AMPATH and LANautilus Engineers have been contacted. Updates will be provided when they are available. |
Ticket No.: | INC0049702 |
Subject: | Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN |
Source Of Impact: | Vendor |
Affected: | FIU026UMI2SA1NN |
Current State: | Closed |
Start Time: | 2020-01-13 23:29:00 |
End Time: | 2020-01-14 06:14:00 |
Description | The listed asset is now available. AMPATH and LANautilus Engineers have been contacted. The reason for the outage was a fiber cut. Repairs have been completed. No further outages are expected. |
Ticket No.: | INC0049712 |
Subject: | Brief Outage - AMPATH Provider LANautilus FIU034WFORSP4NN and FIU033WSA1SP4NN |
Source Of Impact: | Vendor |
Affected: | FIU034WFORSP4NN
FIU033WSA1SP4NN |
Current State: | Resolved |
Start Time: | 2020-01-14 02:55:21 |
End Time: | 2020-01-14 02:56:57 |
Description | The listed assets are available following a brief outage. LANautilus Engineers have been contacted. The reason for the outage is undetermined. No further outages are expected. |
Ticket No.: | INC0049741 |
Subject: | Brief Outage - AMPATH Provider LANautilus FIU034WFORSP4NN |
Source Of Impact: | Vendor |
Affected: | FIU034WFORSP4NN |
Current State: | Closed |
Start Time: | 2020-01-14 14:27:00 |
End Time: | 2020-01-14 14:28:00 |
Description | The listed asset is available following a brief outage. AMPATH and LANautilus Engineers have been contacted. Updates will be provided when they are available. |
Ticket No.: | INC0049782 |
Subject: | Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN |
Source Of Impact: | Vendor |
Affected: | FIU026UMI2SA1NN |
Current State: | Resolved |
Start Time: | 2020-01-15 05:14:41 |
End Time: | 2020-01-15 10:49:16 |
Description | The listed asset is now available. AMPATH and LANautilus Engineers have indicated that the reason for the outage was a fiber cut in Santiago, Chile. The fiber has been repaired. No further outages are expected. |
Ticket No.: | INC0049815 |
Subject: | Brief Outage - AMPATH Provider LANautilus FIU033WSA1SP4NN & FIU034WFORSP4NN |
Source Of Impact: | Vendor |
Affected: | FIU033WSA1SP4NN
FIU034WFORSP4NN |
Current State: | Closed |
Start Time: | 2020-01-15 14:21:00 |
End Time: | 2020-01-15 14:22:00 |
Description | The listed assets are available following a brief outage. AMPATH and LANautilus Engineers have been contacted. Updates will be provided when they are available. |
Ticket No.: | INC0049850 |
Subject: | Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN |
Source Of Impact: | Vendor |
Affected: | FIU026UMI2SA1NN |
Current State: | Closed |
Start Time: | 2020-01-15 22:07:58 |
End Time: | 2020-01-16 07:09:00 |
Description | The listed asset is now available. LANautilus Engineers reported the outage was due to a failed card in StCroix cable station, US Virgin Islands. 100G power stage card DWDM equipment failed. Cold restarts of card failed to restore. Engineer called out and replaced card and services restored. |
Ticket No.: | INC0049885 |
Subject: | Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN |
Source Of Impact: | Vendor |
Affected: | FIU026UMI2SA1NN |
Current State: | Resolved |
Start Time: | 2020-01-16 11:46:15 |
End Time: | 2020-01-16 12:54:07 |
Description | The following assets are available. Lanautilus engineers have reported the outage was due to a defective card in Valparaíso, Chile. |
Ticket No.: | INC0049899 |
Subject: | Brief Outage Resolved - AMPATH Provider LANautilus FIU030WMI2FORNN |
Source Of Impact: | Vendor |
Affected: | FIU030WMI2FORNN |
Current State: | Resolved |
Start Time: | 2020-01-16 15:16:23 |
End Time: | 2020-01-16 15:16:24 |
Description | The listed asset is available following a brief outage. Lanautilus Engineers have been contacted. Engineers have found a brief oscillation in our segment in Saint Croix. All services have stabilized, and no further outages are expected. |
Ticket No.: | INC0049994 |
Subject: | Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN |
Source Of Impact: | Vendor |
Affected: | FIU033WSA1SP4NN |
Current State: | Resolved |
Start Time: | 2020-01-17 16:46:53 |
End Time: | 2020-01-17 18:07:21 |
Description | The listed asset is currently available. Vendor Engineers identified a blocked card in transport equipment located in La Plata, Buenos Aires. Connectivity has been restored and no further outages are expected. |
Ticket No.: | INC0050035 |
Subject: | Brief Outage - AMPATH LANautilus Circuit FIU034WFORSP4NN |
Source Of Impact: | Vendor |
Affected: | FIU034WFORSP4NN |
Current State: | Resolved |
Start Time: | 2020-01-18 08:01:03 |
End Time: | 2020-01-18 08:01:04 |
Description | The listed assets are available following a brief outage. LANautilus Engineers have been contacted but the reason for outage is pending. |
Ticket Number | Customer Impact | Network Impact | Title | Maintenance Type | Source Of Impact | Current State | Start Time (UTC) | End Time (UTC) | Duration |
---|---|---|---|---|---|---|---|---|---|
AMPATH Nodes | Down Time | Reporting Period Availability | 52 Week Availability |
j480.ampath.net | 00 hr 00 min | 100.00000% | 99.98232% |
j480-2.ampath.net | 00 hr 00 min | 100.00000% | 100.00000% |
Aggregate AMPATH Core Nodes | 0 days 0 hr 0 min | 100.00000% | 99.99116% |
AMPATH Backbone Circuits | Down Time | Reporting Period Availability | 52 Week Availability |
FIU033WSA1SP4NN | 1 hr 23 min | 99.17592% | 97.92658% |
FIU030WMI2FORNN | 0 hr 0 min | 99.99983% | 99.87879% |
AMP-JACK-JACK-100GE-52411 | 10 hr 35 min | 93.70039% | 99.29501% |
FIU034WFORSP4NN | 0 hr 4 min | 99.95420% | 99.66498% |
FIU015TCARMI2NN | 00 hr 00 min | 100.00000% | 100.00000% |
FIU026UMI2SA1NN | 22 hr 28 min | 86.62217% | 92.10609% |
FIU031WCRPPANNN | 00 hr 00 min | 100.00000% | 99.99945% |
FIU035WMI2CRPNN | 00 hr 00 min | 100.00000% | 99.54446% |
FIU036WPANSA1NN | 00 hr 00 min | 100.00000% | 98.71212% |
FIU020UMI2SP3NN | 00 hr 00 min | 100.00000% | 98.87582% |
Aggregate All AMPATH Backbone Circuits | 1 days 10 hr 31 min | 97.94525% | 98.60033% |
AMPATH Backbone Circuits | Down Time | Reporting Period Availability | 52 Week Availability |
Ticket No.: | CHG0040588 |
Subject: | Maintenance - AMPATH backbones LANautilus FIU026UMI2SA1NN & FIU036WPANSA1NN |
Source Of Impact: | Vendor |
Affected: | FIU026UMI2SA1NN
FIU036WPANSA1NN |
Start Time: | 2020-01-21 03:00:00 |
End Time: | 2020-01-21 05:00:00 |
Description | The listed assets will be unavailable while LANautilus Engineers perform maintenance. Outages are anticipated. The entire window is reserved. |