AMPATH Network Operations Report
2019-12-30 - 2020-01-05

AMPATH Network Operations Center

New Connections

ConnectorTypeDateSponsor


Upgrades

None


New Services


None


Other


None


Unscheduled Outages Summary

Incident Number Customer Impact Network Impact Title Outage Type Source of Impact Current State Start Time (UTC) End Time (UTC) Duration

INC0049031 4 - Low2 - High Brief Outage Resolved - AMPATH Provider LANautilus FIU034WFORSP4NNUndetermined Vendor Closed 2020-01-02 17:01:15 2020-01-02 17:01:16 0 days 0 hr 0 min

Unscheduled Outages Detail


Ticket No.:INC0049031
Subject:Brief Outage Resolved - AMPATH Provider LANautilus FIU034WFORSP4NN
Source Of Impact: Vendor
Affected:FIU034WFORSP4NN
Current State:Closed
Start Time:2020-01-02 17:01:15
End Time:2020-01-02 17:01:16
DescriptionThe listed asset is available following a brief outage. AMPATH and LANautilus Engineers have been contacted, however, the reason for the outage was unable to be determined.


Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Current State Start Time (UTC) End Time (UTC) Duration

CHG0040119 Maintenance 1 of 2 Completed - AMPATH Backbone AMP-JACK-JACK-100GE-52411 Circuit Vendor Closed 2020-01-02 05:00:002020-01-02 11:00:00 0 days 6 hr 0 min
CHG0040127 Maintenance 2 of 2 Complete - AMPATH Backbone AMP-JACK-JACK-100GE-52411 Circuit Vendor Closed 2020-01-03 05:00:002020-01-03 11:00:00 0 days 6 hr 0 min

Scheduled Maintenances Detail


Ticket No.:CHG0040119
Subject:Maintenance 1 of 2 Completed - AMPATH Backbone AMP-JACK-JACK-100GE-52411
Source Of Impact: Vendor
Affected:AMP-JACK-JACK-100GE-52411
Current State:Closed
Start Time:2020-01-02 05:00:00
End Time:2020-01-02 11:00:00
Description*Please note this is maintenance 1 of 2. The listed asset remained available while Florida Lambda Rail Vendor Engineers performed maintenance to replace fibers in central Georgia. No outages were observed. The maintenance is now complete.


Ticket No.:CHG0040127
Subject:Maintenance 2 of 2 Complete - AMPATH Backbone AMP-JACK-JACK-100GE-52411
Source Of Impact: Vendor
Affected:AMP-JACK-JACK-100GE-52411
Current State:Closed
Start Time:2020-01-03 05:00:00
End Time:2020-01-03 11:00:00
Description*Please note this is maintenance 1 of 2. The listed asset remained available while Florida Lambda Rail Vendor Engineers performed maintenance to replace fibers in central Georgia. No outages were observed. The maintenance is complete


Downtime and Availability



AMPATH NodesDown TimeReporting Period Availability52 Week Availability
j480.ampath.net00 hr 00 min100.00000% 99.98232%
j480-2.ampath.net00 hr 00 min100.00000% 100.00000%

Aggregate AMPATH Core Nodes0 days 0 hr 0 min 100.00000% 99.99116%

AMPATH Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
FIU033WSA1SP4NN00 hr 00 min 100.00000% 100.00000%
FIU030WMI2FORNN00 hr 00 min 100.00000% 99.98707%
AMP-JACK-JACK-100GE-5241112 hr 0 min 92.85713% 99.70044%
FIU034WFORSP4NN0 hr 0 min 99.99983% 100.00000%
FIU015TCARMI2NN00 hr 00 min 100.00000% 100.00000%
FIU026UMI2SA1NN00 hr 00 min 100.00000% 99.96246%
FIU031WCRPPANNN00 hr 00 min 100.00000% 100.00000%
FIU035WMI2CRPNN00 hr 00 min 100.00000% 100.00000%
FIU036WPANSA1NN00 hr 00 min 100.00000% 99.96246%
FIU020UMI2SP3NN00 hr 00 min 100.00000% 99.99929%

Aggregate All AMPATH Backbone Circuits0 days 12 hr 0 min 99.28570% 99.96117%

Availablity by Service

AMPATH Backbone CircuitsDown TimeReporting Period Availability52 Week Availability


Upcoming Scheduled Maintenances

Ticket No.:CHG0040187
Subject:Maintenance - AMPATH Backbone AMP-JACK-JACK-100GE-52411
Source Of Impact: Vendor
Affected:AMP-JACK-JACK-100GE-52411
Start Time:2020-01-08 05:00:00
End Time:2020-01-08 10:00:00
DescriptionThe listed asset will be unavailable while Florida Lambda Rail Vendor Engineers perform maintenance to upgrade hardware. Outages are expected. The entire maintenance window is reserved.