AMPATH Network Operations Report
2019-08-19 - 2019-08-25

AMPATH Network Operations Center

New Connections

ConnectorTypeDateSponsor


Upgrades

None


New Services


None


Other


None


Unscheduled Outages Summary

Incident Number Customer Impact Network Impact Title Outage Type Source of Impact Current State Start Time (UTC) End Time (UTC) Duration

INC0040247 2 - High2 - High Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NNHardware Vendor Closed 2019-08-21 08:27:09 2019-08-21 13:53:33 0 days 5 hr 26 min
INC0040409 4 - Low2 - High Brief Outage Resolved - AMPATH LANautilus Circuit FIU026UMI2SA1NNUndetermined Vendor Resolved 2019-08-22 19:58:57 2019-08-22 19:59:57 0 days 0 hr 1 min
INC0040497 2 - High2 - High Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NNCircuit - Cut Fiber Vendor Resolved 2019-08-23 22:04:40 2019-08-24 05:47:24 0 days 7 hr 42 min

Unscheduled Outages Detail


Ticket No.:INC0040247
Subject:Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NN
Source Of Impact: Vendor
Affected:FIU020UMI2SP3NN
Current State:Closed
Start Time:2019-08-21 08:27:09
End Time:2019-08-21 13:53:33
DescriptionThe following assets are available. LANautilus engineers identified The reason outage is vandalism to a splice Box in Sao Paulo - Brazil. Vendor engineers have restored service.


Ticket No.:INC0040409
Subject:Brief Outage Resolved - AMPATH LANautilus Circuit FIU026UMI2SA1NN
Source Of Impact: Vendor
Affected:FIU026UMI2SA1NN
Current State:Resolved
Start Time:2019-08-22 19:58:57
End Time:2019-08-22 19:59:57
DescriptionThe listed assets are available following a brief outage. Vendor Engineers have been contacted, however, the reason for the outage was unable to be determined.


Ticket No.:INC0040497
Subject:Outage Resolved - AMPATH Provider LANautilus FIU026UMI2SA1NN
Source Of Impact: Vendor
Affected:FIU026UMI2SA1NN
AMPATH Provider LANautilus
Current State:Resolved
Start Time:2019-08-23 22:04:40
End Time:2019-08-24 05:47:24
DescriptionThe following asset is now available. LANautilus engineers have been notified and confirmed there was due to a fiber event in Valparaiso, Chile. The damage has been restored. No further outages are expected.


Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Current State Start Time (UTC) End Time (UTC) Duration

CHG0038305 Maintenance Complete - AMPATH Backbone Circuit JACK-JACK Circuit Vendor Closed 2019-08-21 04:00:002019-08-21 10:00:00 0 days 6 hr 0 min

Scheduled Maintenances Detail


Ticket No.:CHG0038305
Subject:Maintenance Complete - AMPATH Backbone Circuit JACK-JACK
Source Of Impact: Vendor
Affected:AMP-JACK-JACK-100GE-52411
Current State:Closed
Start Time:2019-08-21 04:00:00
End Time:2019-08-21 10:00:00
DescriptionThe listed asset is now available after Century Link Engineers performed maintenance. The maintenance is complete.


Downtime and Availability



AMPATH NodesDown TimeReporting Period Availability52 Week Availability
j480.ampath.net00 hr 00 min100.00000% 99.98232%
j480-2.ampath.net00 hr 00 min100.00000% 100.00000%

Aggregate AMPATH Core Nodes0 days 0 hr 0 min 100.00000% 99.99116%

AMPATH Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
FIU033WSA1SP4NN00 hr 00 min 100.00000% 96.00805%
FIU030WMI2FORNN00 hr 00 min 100.00000% 97.39785%
AMP-JACK-JACK-100GE-524116 hr 0 min 96.42857% 3.08460%
FIU034WFORSP4NN00 hr 00 min 100.00000% 95.52975%
FIU015TCARMI2NN00 hr 00 min 100.00000% 100.00000%
FIU026UMI2SA1NN7 hr 43 min 95.39946% 98.58615%
FIU031WCRPPANNN00 hr 00 min 100.00000% 100.00000%
FIU035WMI2CRPNN00 hr 00 min 100.00000% 99.41971%
FIU036WPANSA1NN00 hr 00 min 100.00000% 99.20581%
FIU020UMI2SP3NN5 hr 26 min 96.76190% 99.26947%

Aggregate All AMPATH Backbone Circuits0 days 19 hr 10 min 98.85899% 88.85014%

Availablity by Service

AMPATH Backbone CircuitsDown TimeReporting Period Availability52 Week Availability


Upcoming Scheduled Maintenances

None Currently Planned