AMPATH Network Operations Report
2019-08-05 - 2019-08-11
AMPATH Network Operations Center
Connector | Type | Date | Sponsor |
---|
None
None
None
Incident Number | Customer Impact | Network Impact | Title | Outage Type | Source of Impact | Current State | Start Time (UTC) | End Time (UTC) | Duration |
---|---|---|---|---|---|---|---|---|---|
INC0039335 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU020UMI2SP3NN | Undetermined | Vendor | Resolved | 2019-08-06 15:08:47 | 2019-08-06 15:08:50 | 0 days 0 hr 0 min |
INC0039349 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU026UMI2SA1NN | Undetermined | Vendor | Resolved | 2019-08-06 17:12:35 | 2019-08-06 17:13:35 | 0 days 0 hr 1 min |
INC0039365 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU036WPANSA1NN | Undetermined | Vendor | Resolved | 2019-08-06 19:06:01 | 2019-08-06 19:06:30 | 0 days 0 hr 0 min |
INC0039390 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU036WPANSA1NN | Undetermined | Vendor | Resolved | 2019-08-07 00:28:57 | 2019-08-07 00:29:49 | 0 days 0 hr 0 min |
INC0039514 | 4 - Low | 2 - High | Brief Outage - AMPATH Provider LANautilus FIU026UMI2SA1NN & FIU036WPANSA1NN | Circuit - Cut Fiber | Vendor | Closed | 2019-08-08 21:00:23 | 2019-08-08 21:01:23 | 0 days 0 hr 1 min |
INC0039588 | 2 - High | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NN | Circuit - Vandalism | Vendor | Resolved | 2019-08-10 01:40:48 | 2019-08-10 08:58:52 | 0 days 7 hr 18 min |
INC0039634 | 4 - Low | 2 - High | Brief Outage - AMPATH LANautilus Circuit FIU026UMI2SA1NN | Circuit - Other | Vendor | Resolved | 2019-08-11 20:51:09 | 2019-08-11 20:51:45 | 0 days 0 hr 0 min |
Ticket No.: | INC0039335 |
Subject: | Brief Outage - AMPATH Provider LANautilus FIU020UMI2SP3NN |
Source Of Impact: | Vendor |
Affected: | FIU020UMI2SP3NN |
Current State: | Resolved |
Start Time: | 2019-08-06 15:08:47 |
End Time: | 2019-08-06 15:08:50 |
Description | The listed asset was briefly unavailable. LANautilus Engineers have been contacted to investigate. |
Ticket No.: | INC0039349 |
Subject: | Brief Outage - AMPATH Provider LANautilus FIU026UMI2SA1NN |
Source Of Impact: | Vendor |
Affected: | FIU026UMI2SA1NN |
Current State: | Resolved |
Start Time: | 2019-08-06 17:12:35 |
End Time: | 2019-08-06 17:13:35 |
Description | The listed asset is now available. Vendor Engineers have been contacted, however the reason for the outage is indeterminate. |
Ticket No.: | INC0039365 |
Subject: | Brief Outage - AMPATH Provider LANautilus FIU036WPANSA1NN |
Source Of Impact: | Vendor |
Affected: | FIU036WPANSA1NN |
Current State: | Resolved |
Start Time: | 2019-08-06 19:06:01 |
End Time: | 2019-08-06 19:06:30 |
Description | The listed asset is available. LANautilus Engineers have been contacted to investigate. |
Ticket No.: | INC0039390 |
Subject: | Brief Outage - AMPATH Provider LANautilus FIU036WPANSA1NN |
Source Of Impact: | Vendor |
Affected: | FIU036WPANSA1NN
AMPATH Provider LANautilus |
Current State: | Resolved |
Start Time: | 2019-08-07 00:28:57 |
End Time: | 2019-08-07 00:29:49 |
Description | The following asset is now available after a brief outage. LANautilus engineers have been notified. The reason for the outage is pending |
Ticket No.: | INC0039514 |
Subject: | Brief Outage - AMPATH Provider LANautilus FIU026UMI2SA1NN & FIU036WPANSA1NN |
Source Of Impact: | Vendor |
Affected: | FIU026UMI2SA1NN
FIU036WPANSA1NN |
Current State: | Closed |
Start Time: | 2019-08-08 21:00:23 |
End Time: | 2019-08-08 21:01:23 |
Description | The listed assets are available following a brief outage. Vendor engineers have been contacted to investigate this event. Updates will be available when it they are available. |
Ticket No.: | INC0039588 |
Subject: | Outage Resolved - AMPATH Provider LANautilus FIU020UMI2SP3NN |
Source Of Impact: | Vendor |
Affected: | FIU020UMI2SP3NN |
Current State: | Resolved |
Start Time: | 2019-08-10 01:40:48 |
End Time: | 2019-08-10 08:58:52 |
Description | The listed assets are now available. Provider LANautilus has been contacted and confirmed the outage was due to a fiber cut in Carapicuiba, Brazil caused by vandalism. Fiber repair crews have completed repairs on the damaged segment. No further outages are expected. |
Ticket No.: | INC0039634 |
Subject: | Brief Outage - AMPATH LANautilus Circuit FIU026UMI2SA1NN |
Source Of Impact: | Vendor |
Affected: | FIU026UMI2SA1NN |
Current State: | Resolved |
Start Time: | 2019-08-11 20:51:09 |
End Time: | 2019-08-11 20:51:45 |
Description | The listed assets are available after a brief outage. Vendor Engineers have been contacted . The reason for the outage is due to degradation in a terrestrial back-haul. No further outages are expected. |
Ticket Number | Customer Impact | Network Impact | Title | Maintenance Type | Source Of Impact | Current State | Start Time (UTC) | End Time (UTC) | Duration |
---|---|---|---|---|---|---|---|---|---|
AMPATH Nodes | Down Time | Reporting Period Availability | 52 Week Availability |
j480.ampath.net | 00 hr 00 min | 100.00000% | 99.98232% |
j480-2.ampath.net | 00 hr 00 min | 100.00000% | 100.00000% |
Aggregate AMPATH Core Nodes | 0 days 0 hr 0 min | 100.00000% | 99.99116% |
AMPATH Backbone Circuits | Down Time | Reporting Period Availability | 52 Week Availability |
FIU033WSA1SP4NN | 00 hr 00 min | 100.00000% | 96.09193% |
FIU030WMI2FORNN | 00 hr 00 min | 100.00000% | 97.39785% |
AMP-JACK-JACK-100GE-52411 | 00 hr 00 min | 100.00000% | 6.97804% |
FIU034WFORSP4NN | 00 hr 00 min | 100.00000% | 95.59473% |
FIU015TCARMI2NN | 00 hr 00 min | 100.00000% | 100.00000% |
FIU026UMI2SA1NN | 0 hr 2 min | 99.97421% | 98.67463% |
FIU031WCRPPANNN | 00 hr 00 min | 100.00000% | 100.00000% |
FIU035WMI2CRPNN | 00 hr 00 min | 100.00000% | 99.41990% |
FIU036WPANSA1NN | 0 hr 2 min | 99.97669% | 99.20614% |
FIU020UMI2SP3NN | 7 hr 18 min | 95.65360% | 99.74399% |
Aggregate All AMPATH Backbone Circuits | 0 days 7 hr 23 min | 99.56045% | 89.31072% |
AMPATH Backbone Circuits | Down Time | Reporting Period Availability | 52 Week Availability |