AMPATH Network Operations Report
2019-02-18 - 2019-02-24

AMPATH Network Operations Center

New Connections

ConnectorTypeDateSponsor


Upgrades

None


New Services


None


Other


None


Unscheduled Outages Summary

Incident Number Customer Impact Network Impact Title Outage Type Source of Impact Current State Start Time (UTC) End Time (UTC) Duration

INC0028958 4 - Low2 - High Brief Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NNCircuit - Other Vendor Resolved 2019-02-19 17:34:54 2019-02-19 17:35:54 0 days 0 hr 1 min
INC0029031 4 - Low2 - High Brief Outage - AMPATH Provider LANautilus FIU030WMI2FORNN Circuit - Cut Fiber Vendor Resolved 2019-02-20 16:47:00 2019-02-20 16:48:00 0 days 0 hr 1 min
INC0029030 2 - High2 - High Outage Resolved - AMPATH Provider LANautilus FIU035WMI2CRPNNCircuit - Cut Fiber Other Resolved 2019-02-20 16:47:00 2019-02-21 01:49:20 0 days 9 hr 2 min
INC0029102 4 - Low2 - High Brief Outage - AMPATH LANautilus Circuit FIU035WMI2CRPNNUndetermined Vendor Resolved 2019-02-21 16:19:44 2019-02-21 16:20:00 0 days 0 hr 0 min
INC0029269 4 - Low2 - High Brief Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN and FIU034WFORSP4NNHardware Vendor Resolved 2019-02-24 18:48:29 2019-02-24 18:48:30 0 days 0 hr 0 min

Unscheduled Outages Detail


Ticket No.:INC0028958
Subject:Brief Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN
Source Of Impact: Vendor
Affected:FIU033WSA1SP4NN
LANautilus
Current State:Resolved
Start Time:2019-02-19 17:34:54
End Time:2019-02-19 17:35:54
DescriptionThe listed asset is available following a brief outage. LANautilus Engineers reported the outage was due to a circuit degradation in their terrestrial backhaul between Rafaela - Barranas, Argentina. All services have been restored. No further outage is expected.


Ticket No.:INC0029031
Subject:Brief Outage - AMPATH Provider LANautilus FIU030WMI2FORNN
Source Of Impact: Vendor
Affected:FIU030WMI2FORNN
Provider LANautilus FIU030WMI2FORNN
Current State:Resolved
Start Time:2019-02-20 16:47:00
End Time:2019-02-20 16:48:00
DescriptionThe listed assets are available. Vendor Engineers have been contacted and confirmed the outage was due to a fiber cut. Repair crews are on site working to restore connectivity.


Ticket No.:INC0029030
Subject:Outage Resolved - AMPATH Provider LANautilus FIU035WMI2CRPNN
Source Of Impact: Other
Affected:FIU035WMI2CRPNN
Current State:Resolved
Start Time:2019-02-20 16:47:00
End Time:2019-02-21 01:49:20
DescriptionThe listed assets are available. Vendor Engineers were contacted, the reason for the outage was a fiber cut.


Ticket No.:INC0029102
Subject:Brief Outage - AMPATH LANautilus Circuit FIU035WMI2CRPNN
Source Of Impact: Vendor
Affected:FIU035WMI2CRPNN
LANautilus Circuit FIU035WMI2CRPNN
Current State:Resolved
Start Time:2019-02-21 16:19:44
End Time:2019-02-21 16:20:00
DescriptionThe listed asset is now available after a brief outage. LANautilus engineers have been contacted; however the reason for the outage is pending.


Ticket No.:INC0029269
Subject:Brief Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN and FIU034WFORSP4NN
Source Of Impact: Vendor
Affected:FIU033WSA1SP4NN
FIU034WFORSP4NN
Current State:Resolved
Start Time:2019-02-24 18:48:29
End Time:2019-02-24 18:48:30
DescriptionThe listed asset is available following a brief outage. LANautilus Engineers reported the outage was due to one card that dropped some errors in one of their equipment in Sao Paulo, Brazil. After restarted the card, all services have been restored and no further outage is expected.


Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Current State Start Time (UTC) End Time (UTC) Duration


Scheduled Maintenances Detail


None during this report period

Downtime and Availability



AMPATH NodesDown TimeReporting Period Availability52 Week Availability
j480.ampath.net00 hr 00 min100.00000% 100.00000%
j480-2.ampath.net00 hr 00 min100.00000% 100.00000%

Aggregate AMPATH Core Nodes0 days 0 hr 0 min 100.00000% 100.00000%

AMPATH Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
FIU033WSA1SP4NN0 hr 1 min 99.98991% 96.81091%
FIU030WMI2FORNN0 hr 1 min 99.99008% 97.42065%
AMP-JACK-JACK-100GE-5241100 hr 00 min 100.00000% 97.22241%
FIU034WFORSP4NN0 hr 0 min 99.99983% 95.61314%
FIU020UMI2SP1NN00 hr 00 min 100.00000% 91.57398%
FIU015TCARMI2NN00 hr 00 min 100.00000% 100.00000%
FIU026UMI2SA1NN00 hr 00 min 100.00000% 99.22527%
FIU031WCRPPANNN00 hr 00 min 100.00000% 100.00000%
FIU035WMI2CRPNN9 hr 2 min 94.61705% 99.73756%
FIU036WPANSA1NN00 hr 00 min 100.00000% 100.00000%

Aggregate All AMPATH Backbone Circuits0 days 9 hr 4 min 99.45969% 97.76039%



Upcoming Scheduled Maintenances

None Currently Planned