AMPATH Network Operations Report
2021-04-05 - 2021-04-11
AMPATH Network Operations Center
Connector | Type | Date | Sponsor |
---|
None
None
None
Incident Number | Customer Impact | Network Impact | Title | Outage Type | Source of Impact | Current State | Start Time (UTC) | End Time (UTC) | Duration |
---|---|---|---|---|---|---|---|---|---|
INC0080168 | 2 - High | 2 - High | Outage Resolved - AMPATH LANautilus Circuit FIU033WSA1SP4NN | Unannounced Maintenance | Vendor | Resolved | 2021-04-06 04:29:06 | 2021-04-06 05:15:20 | 0 days 0 hr 46 min |
INC0080184 | 4 - Low | 2 - High | Brief Outage Resolved - AMPATH Provider LANautilus FIU034WFORSP4NN | Undetermined | Vendor | Closed | 2021-04-06 14:30:56 | 2021-04-06 14:31:00 | 0 days 0 hr 0 min |
INC0080243 | 2 - High | 2 - High | Outage Resolved - AMPATH LANautilus Circuit FIU033WSA1SP4NN | Unannounced Maintenance | Vendor | Resolved | 2021-04-07 05:03:11 | 2021-04-07 09:17:24 | 0 days 4 hr 14 min |
INC0080282 | 4 - Low | 2 - High | Brief Outage - AMPATH Backbone Circuit JACKSONVILLE-MIAMI (Primary) | Undetermined | Vendor | Resolved | 2021-04-07 16:09:17 | 2021-04-07 16:10:00 | 0 days 0 hr 0 min |
INC0080348 | 2 - High | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN | Unannounced Maintenance | Vendor | Resolved | 2021-04-08 04:53:26 | 2021-04-08 05:55:26 | 0 days 1 hr 2 min |
INC0080430 | 2 - High | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN | Undetermined | Vendor | Resolved | 2021-04-08 23:05:25 | 2021-04-09 00:03:27 | 0 days 0 hr 58 min |
INC0080455 | 2 - High | 2 - High | Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN | Unannounced Maintenance | Vendor | Resolved | 2021-04-09 04:39:32 | 2021-04-09 07:22:00 | 0 days 2 hr 42 min |
Ticket No.: | INC0080168 |
Subject: | Outage Resolved - AMPATH LANautilus Circuit FIU033WSA1SP4NN |
Source Of Impact: | Vendor |
Affected: | FIU033WSA1SP4NN |
Current State: | Resolved |
Start Time: | 2021-04-06 04:29:06 |
End Time: | 2021-04-06 05:15:20 |
Outgoing Notification Text | The listed assets are now available. Vendor Engineers have reported the outage was due to maintenance which has concluded. |
Ticket No.: | INC0080184 |
Subject: | Brief Outage Resolved - AMPATH Provider LANautilus FIU034WFORSP4NN |
Source Of Impact: | Vendor |
Affected: | FIU034WFORSP4NN |
Current State: | Closed |
Start Time: | 2021-04-06 14:30:56 |
End Time: | 2021-04-06 14:31:00 |
Outgoing Notification Text | The listed asset is available following a brief outage. AMPATH and LANautilus Engineers have been contacted. UThe reason for the outage is undetermined. |
Ticket No.: | INC0080243 |
Subject: | Outage Resolved - AMPATH LANautilus Circuit FIU033WSA1SP4NN |
Source Of Impact: | Vendor |
Affected: | FIU033WSA1SP4NN |
Current State: | Resolved |
Start Time: | 2021-04-07 05:03:11 |
End Time: | 2021-04-07 09:17:24 |
Outgoing Notification Text | The listed assets are now available. LANautilus Engineers reported the outage was due to maintenance. |
Ticket No.: | INC0080282 |
Subject: | Brief Outage - AMPATH Backbone Circuit JACKSONVILLE-MIAMI (Primary) |
Source Of Impact: | Vendor |
Affected: | AMP-JACKSONVILLE-MIAMI-100GE-01502 |
Current State: | Resolved |
Start Time: | 2021-04-07 16:09:17 |
End Time: | 2021-04-07 16:10:00 |
Outgoing Notification Text | The listed asset is available following a brief outage. FIU Engineers have been contacted. Updates will be provided when they are available. |
Ticket No.: | INC0080348 |
Subject: | Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN |
Source Of Impact: | Vendor |
Affected: | FIU033WSA1SP4NN |
Current State: | Resolved |
Start Time: | 2021-04-08 04:53:26 |
End Time: | 2021-04-08 05:55:26 |
Outgoing Notification Text | The listed asset is available. LANautilus Engineers have been contacted and identified the outage to a maintenance. Maintenance has been completed and no further impact expected. |
Ticket No.: | INC0080430 |
Subject: | Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN |
Source Of Impact: | Vendor |
Affected: | FIU033WSA1SP4NN |
Current State: | Resolved |
Start Time: | 2021-04-08 23:05:25 |
End Time: | 2021-04-09 00:03:27 |
Outgoing Notification Text | The listed asset is available following an outage. AMPATH and LANautilus Engineers have been contacted. The reason for the outage is undetermined. |
Ticket No.: | INC0080455 |
Subject: | Outage Resolved - AMPATH Provider LANautilus FIU033WSA1SP4NN |
Source Of Impact: | Vendor |
Affected: | FIU033WSA1SP4NN |
Current State: | Resolved |
Start Time: | 2021-04-09 04:39:32 |
End Time: | 2021-04-09 07:22:00 |
Outgoing Notification Text | FIU033WSA1SP4NN is currently available. Provider LANautilus has stated the outage was caused by planned maintenance. The maintenance is complete. |
Ticket Number | Customer Impact | Network Impact | Title | Maintenance Type | Source Of Impact | Current State | Start Time (UTC) | End Time (UTC) | Duration |
---|---|---|---|---|---|---|---|---|---|
AMPATH Nodes | Down Time | Reporting Period Availability | 52 Week Availability |
BocaRaton-NE4-1-1 | 00 hr 00 min | 100.00000% | 100.00000% |
j480.ampath.net | 00 hr 00 min | 100.00000% | 100.00000% |
WS-Ai-MI3-1 | 00 hr 00 min | 100.00000% | 100.00000% |
WS-Ai-MI1-1 | 00 hr 00 min | 100.00000% | 100.00000% |
Miami-NE3-1-1 | 00 hr 00 min | 100.00000% | 100.00000% |
j480-2.ampath.net | 00 hr 00 min | 100.00000% | 100.00000% |
Aggregate AMPATH Core Nodes | 0 days 0 hr 0 min | 100.00000% | 100.00000% |
AMPATH Backbone Circuits | Down Time | Reporting Period Availability | 52 Week Availability |
FIU033WSA1SP4NN | 9 hr 42 min | 94.21676% | 98.49462% |
MON- FIU/FTZ-MI3_WAVE-003 | 00 hr 00 min | 100.00000% | 99.99981% |
FIU030WMI2FORNN | 00 hr 00 min | 100.00000% | 99.98815% |
FIU034WFORSP4NN | 0 hr 0 min | 99.99934% | 99.20594% |
FIU015TCARMI2NN | 00 hr 00 min | 100.00000% | 100.00000% |
AMP-JACKSONVILLE-MIAMI-100GE-01503 | 00 hr 00 min | 100.00000% | 98.92239% |
SACS/FIU_RNP/FTZ-SGN/100G_FP3 | 00 hr 00 min | 100.00000% | 100.00000% |
FIU026UMI2SA1NN | 00 hr 00 min | 100.00000% | 97.48479% |
MON- FIU/MI3-SP3_WAVE-001 | 00 hr 00 min | 100.00000% | 100.00000% |
AMP-JACKSONVILLE-MIAMI-100GE-01502 | 0 hr 0 min | 99.99289% | 99.73054% |
FIU031WCRPPANNN | 00 hr 00 min | 100.00000% | 99.72191% |
FIU035WMI2CRPNN | 00 hr 00 min | 100.00000% | 99.06901% |
FIU036WPANSA1NN | 00 hr 00 min | 100.00000% | 99.71773% |
AMPATH-BOCA-MIAMI-DF | 00 hr 00 min | 100.00000% | 99.86339% |
FIU020UMI2SP3NN | 00 hr 00 min | 100.00000% | 99.09218% |
Aggregate All AMPATH Backbone Circuits | 0 days 9 hr 43 min | 99.61393% | 99.41936% |
AMPATH Backbone Circuits | Down Time | Reporting Period Availability | 52 Week Availability |